Grey cast iron is one of the most prominent iron products that has its application worldwide. The foundations of the machine tool and the body of an internal combustion engine are the critical cast iron applications. But one of the problem in cast iron is the wearing of surface, which generally occurs in grey cast iron. Various researchers have investigated this phenomenon and have put forward their observation. This paper pen down their investigations on wear effect and discusses some investigations on laser surface hardening to improve the cast iron's characteristic.

Keywords

Cast Iron, Wear, Laser Surface Hardening


  1. Johnson. E. Global warming from HFC. Environ. Impact Asses. 18, 1998, 485-492

  2. QiyuChen, R. C Prasad. Simulation of a vapour compression refrigeration cycles HFC134A and CFC12.Int Comm.Heat Mass Transfer. 26, 1999; 513-521

  3. M. Padilla, R. Revellin, J. Bonjour. Exergy analysis of R413A as replacement of R12 in a domestic refrigeration system. Int J Energy Conversion and Management, 51, 2010, 2195-2201

  4. 0H.O. Spauschus, HFC 134a as a substitute refrigerant for CFC 12. Int J of Refrigeration, 11, 1988, 389-392

  5. J. U. Ahamed, R.Saidur, H. H.Masjuki, A review on exergy analysis of vapor compression refrigeration system. Int J Renewable and sustainable energy reviews, 15, 2011, 1593-1600

  6. R. L lopis, E. Torrella, R. Cabello, D. Sánchez. Performance evaluation of R404A and R507A refrigerant mixtures in an experimental double-stage of vapour compression plant. Int J Applied Energy, 87, 2010, 1546-1553

  7. Akhilesh Arora, S. C. Kaushik, Theoretical analysis of a vapour compression refrigeration system with R502, R404A and R507A. Int J Refrigeration, 31, 2008, 998-1005

  8. V. Havelsky. Investigation of refrigerating system with R12 refrigerant replacements .Int J Applied Thermal Engineering, 2000; 20:133-140

  9. V. Siva Reddy, N. L Panwar, S. C Kaushik, Exergy analysis of a vapour compression refrigeration system with R134a,R143a,R152a,R404A,R407C,R410A,R502 and R507A.Clean Techn Environ Policy, 14, 2012, 47-53

  10. R. Saravanakumar, V. Selladurai, Exergy analysis of a domestic refrigerator using eco-friendly R290/R600a refrigerant mixture as an alternative to R134a.Int J Therm Anal Calorim.2013

  11. C. Nikolaidis, D. Probert-Exergy method analysis of a two-stage vapour-compression refrigeration-plants performance. Int J Applied Thermal Engineering, 60, 1998, 241-256

  12. S. Kumar, M. Prevost, R. Bugarel, Exergy analysis of a vapour compression refrigeration system. Heat Recovery Systems & CHP, 9, 1989, 151-157

  13. Mahmood Mastani Joybari, Mohammad Sadegh Hatamipour, Amir Rahimi, Fatemeh Ghadiri Modarres-Exergy analysis and optimization of R600a as a replacement of R134a in a domestic refrigerator system. International Journal of refrigeration, 36, 2013, 1233-1242

  14. S. Anand, S. K Tyagi, Exergy analysis and experimental study of a vapour compression refrigeration cycle.Int J Therm Anal Calorim, 110, 2012, 961-971

  15. J. U Ahamed, R.saidur, H.H Masjuki, M. A Sattar, An analysis of energy, exergy and sustainable development of a vapour compression refrigeration system using hydrocarbon.International journal of Green energy, 9, 2012, 707-717

  16. Camelia Stanciu, Adina Gheorghian, Dorin Stanciu, Alexandru Dobrovicescu- Exergy analysis and refrigerant effect on the operation and performance lomits of a one stage vapour compression refrigeration system.Termotehnica, 1, 2011, 36-42

  17. J. U. Ahamed, R. Saidur, H. H. Masjuki, A review on exergy analysis of vapor compression refrigeration system. Int J Renewable and sustainable energy reviews, 15, 2011, 1593-1600

  18. B. O. Bolaji, M. A. Akintunde, T. O. Falade, Comparative analysis of performance of three ozone-friends HFC refrigerants in a vapor compression refrigerator. Int J Sustainable Energy & Environment, 2, 2011, 61-64

  19. RecepYumrutas, Mehmet Kunduz, Mehmet Kanoglu-Exergy analysis of vapor compression refrigeration systems. Exergy, An International Journal, 2, 2002, 266-272

  20. M. Padilla, R. Revellin, J. Bonjour, Exergy analysis of R413A as replacement of R12 in a domestic refrigeration system. Int J Energy Conversion and Management, 51, 2010; 2195-2201

  21. H. M Getu, P. K Bansal, Thermodynamic analysis of an R744-R717 cascade refrigeration system. Int J Refrigeration, 31, 2008, 45-54

  22. Mark W. Spatz, Samuel F. Yana Motta. An evaluation of options for replacing HCFC-22 in medium temperature refrigeration systems. Int J Refrigeration, 27, 2004, 475-483

  23. M. Mohanraj, S. Jayaraj, C. Muraleedharan, P. Chandrasekar, Experimental investigation of R290/R600a mixture as an alternative to R134a in a

Abstract Views: 4
PDF Views: 97

Advanced Search

News/Events

Indira School of Bus...

Indira School of Mangement Studies PGDM, Pune Organizing Internatio...

Indira Institute of ...

Indira Institute of Management, Pune Organizing International Confe...

D. Y. Patil Internat...

D. Y. Patil International University, Akurdi-Pune Organizing Nation...

ISBM College of Engi...

ISBM College of Engineering, Pune Organizing International Conferen...

Periyar Maniammai In...

Department of Commerce Periyar Maniammai Institute of Science &...

Institute of Managem...

Vivekanand Education Society's Institute of Management Studies ...

Institute of Managem...

Deccan Education Society Institute of Management Development and Re...

S.B. Patil Institute...

Pimpri Chinchwad Education Trust's S.B. Patil Institute of Mana...

D. Y. Patil IMCAM, A...

D. Y. Patil Institute of Master of Computer Applications & Managem...

Vignana Jyothi Insti...

Vignana Jyothi Institute of Management International Conference on ...

By continuing to use this website, you consent to the use of cookies in accordance with our Cookie Policy.