Vol 7 , Issue 3 , July - September 2019 | Pages: 110-114 | Research Paper
Received: May 13, 2019 | Revised: May 20, 2019 | Accepted: May 28, 2019 | Published Online: June 15, 2019
Author Details
( * ) denotes Corresponding author
The Study present in this article focuses on the research of alternate eco friendly refrigerants with remarkable coefficient of performance and reduced global warning potential and zero ozone depletion potential. Objective of this experimental investigation is to study the performance of R134a and R152a and R1234 yf refrigerant in vapor compression cycle and their comparison with various parameter. The result showed the alternative refrigerant R1234 yf investigated in the analysis have higher coefficient of performance than R152 a and lower than R134a. This experimental investigation is conducted on vapor compression refrigeration Test Rig in applied thermodynamic lab of Khalsa College of Engg. and Technology.
Keywords
Coefficient of Performance; Global Warming Potential; Ozone Depletion Potential.